- FW831 | Maple Armor
FW831 RELAY MODULE The FW831 is an addressable relay module that provides two control relay outputs which will be activated simultaneously. The active status of the relay output is indicated by flashing red LED. VIEW DATASHEET FIRE ALARM RELAY MODULE The FW831 is an addressable module and takes one address on the addressable loop (ALU) of the fire alarm control panel. It is a UL listed product according to UL864 and ULC-S527 for Fire Protective Signaling Systems for indoor use. Relays are form-C with all contacts accessible. Capabilities The relay alarm module FW831 provides two control relay outputs which will be activated simultaneously. When the outputs are activated, the device LED will indicate the event condition by fast blinking. Compliance UL864 / ULC S527 Output Configurations It supports both normally closed and normally open output contact configurations. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 The relay model contact Rating: 30VDC 2A, 0.35pf Operating Temperature: 32°F to 120°F (0°C to 49°C) Operating Humidity: 0% to 93% RH Voltage Range: 15 to 28VDC Mounting: FW800 Base
- ALARM PANELS | Maple Armor
ADDRESSABLE FIRE ALARM PANELS Maple Armor supplies you with intelligent and addressable fire alarm control panels that are ideally suited for both new and retrofit commercial, institutional, residential and industrial fire detection and notification applications. ABOUT OUR PRODUCTS Maple Armor provides you with nothing but reliable, robust and cost-effective fire alarm devices. All our equipment is UL, ULC, FCC listed as well as FM approved and conform to the highest standards of life safety and property loss prevention. LEARN MORE FW106S FIRE ALARM CONTROL PANEL Addressable Fire Alarm Control Panel Designed for small and medium scale facilities Suited for both new and retrofit commercial, institutional and industrial fire detection and notification applications. It can support up to 252 Addressable Devices , 2-4 Notification Circuits and 5 Form C Relay Compatible with XNU FW357 Network Card LEARN MORE FW131 ADDRESSABLE NAC BOOSTER 8 Class A or B signaling circuits with a max of 3A per NAC circuit 12A Compact Switching power supply 110 – 120 VAC 60Hz, or 220 – 240 VAC 50Hz 10A power dedicate to signaling circuits 1A Auxiliary power output 4 form C dry relay contacts 3 ways to connect between panels and NAC Boosters – via SLC, via CAN and Pass Through LEARN MORE FW106 FIRE ALARM CONTROL PANEL Addressable Fire Alarm Control Panel Designed for small, medium and large scale facilities Suited for both new and retrofit commercial, institutional and industrial fire detection and notification applications. It can support up to 1008 Addressable Devices , 10 Notification Circuits and 5 Form C Relay Compatible with XNU FW357 Network Card LEARN MORE FW105 ADDRESSABLE FIRE ALARM PANEL Addressable Fire Alarm Control Panel Designed for small and medium scale facilities Built-in 30 LED/buttons annunciator It can support up to 252 Addressable Devices , 4 to 8 Notification Circuits and 5 Form C Relay 6 auxiliary function buttons and 12 LED indicators. LEARN MORE
- FW821 | Maple Armor
FW821 FIRE ALARM I/O MODULE The input-output module FW821 is a UL / ULC listed device according to UL864 and ULC-S527 for fire protection signaling systems for indoor use. VIEW DATASHEET FIRE ALARM I/O MODULE The input line is monitored for open line faults and ground faults, and the contact must thus be wired with an end-of-line resistor. The output line is monitored for open lines, short-circuit faults, ground faults, and external 24VDC power source loss. Capabilities The FW821 input-output module provides one 24VDC output and one feedback input monitor. Compliance UL864 / ULC S527 / FM Listed Addressable The FW821 is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 Useful to confirm a retroactive action Internal electronic address Compatible with EOLR 10K Ohms (FW421) White surface box available as an option (FW800/801) Status LED indicator
- FW6000-B12260 | Maple Armor
FW6000-B12260 VIEW DATASHEET MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718
- FW511 | Maple Armor
FW511 ADDRESSABLE PHOTOELECTRIC SMOKE DETECTOR The smoke detector features a slim design that combines visual appeal with a high standard of reliability. It responds quickly and dependably to a broad range of fires. VIEW DATASHEET PHOTOELECTRIC SMOKE DETECTOR The addressable Smoke Detector FW511 is used with the FW501 Detector Base. It is a UL and ULC listed device according to UL 268 and ULC-S529 for Fire Protective Signaling Systems for indoor use. Capabilities The detector has a Microcontroller Unit (MCU), allowing it to complete comprehensive self-diagnostic tests and result analysis. Compliance UL/ULC/FM/FCC Listed Addressable The FW511 is intelligent, addressable, and takes one address on the Signaling Line Circuit (SLC) of the fire alarm control panel. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 Its slim design combines visual appeal with a high standard of reliability. It responds quickly and dependably to a broad range of fires. Smoke Sensitivity: 1.6% ft to2.3% ft Operating Temperature: 32°F to 100°F (0°C to 38°C) Wall or Ceiling Mounting
- FW971 | Maple Armor
FW971 CONVENTIONAL NOTIFICATION HORN The Fire Alarm Horn has a built-in synchronization circuit that can synchronize multiple horns in a complete fire alarm system. VIEW DATASHEET CONVENTIONAL NOTIFICATION HORN The FW971 Horn is an audible signal appliances for indoor use. Capabilities The temporal tone generated by the horn is designed as per ANSI and NFPA72 for standard emergency evacuation signaling requirements. Compliance UL/ULC/FM/FCC listed Output The default setting is High, but where allowed and the users may select the Low setting MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 There are up to 64 Notification Appliance Circuits (NAC), networked, stand alone or interfacing with the Sync Module FW951. Wall or Ceiling Mounting
- FW106S | Maple Armor
FW106S FIRE ALARM CONTROL PANEL The FW106S is an addressable Fire Alarm Control Panel designed for small scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. VIEW DATASHEET FIRE ALARM CONTROL PANEL A state-of-the-art addressable fire control system that meets the requirements of UL864 10th edition, and ULC S527. It can support 1 addressable loop unit and 252 addressable devices/points, with 2 to 4 Notification Appliance Circuits and 5 form C dry relay contacts. FW106S (DG) Addressable Fire Control Panel (Grey) FW433 - TRIM Capabilities Intelligent Fire Alarm Control Panel designed for small scale facilities Compliance UL/ULC listed according to UL864 10th edition and ULC-S527 3rd edition Addressable Devices Supports 1 addressable loop circuit and 252 addressable devices/points. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 Ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. Supports 2 to 4 Notification Appliance Circuits and 5 form C dry relay contacts. Supports 109 remote annunciators. Includes a 7” color LCD display with 800×480 resolution, 6 auxiliary function keys and 9 LED indicators making it a highly intuitive fire-alarm user interface PAS (positive alarm sequence) Two-stage Alarm (ULC) Alarm verification Silence Inhibitor Trouble/Supervisory Resound Simultaneous display of active events on large graphic LCD Fully programmable from the front panel
- 6-FM-5 12V5Ah | Maple Armor
6-FM-5 12V5Ah VIEW DATASHEET MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718
- FW6000-B650 | Maple Armor
FW6000-B650 VIEW DATASHEET MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718
- DETECTORS | Maple Armor
HEAT & SMOKE DETECTORS Our addressable and intelligent detectors have a slim design that allows them to be integrated into any type of building. ABOUT OUR PRODUCTS Maple Armor provides you with nothing but reliable, robust and cost-effective fire alarm devices. All our equipment is UL, ULC, FCC listed as well as FM approved and conform to the highest standards of life safety and property loss prevention. LEARN MORE FW511 SMOKE DETECTOR It responds quickly and dependably to a broad range of fire types. Its slim design combines visual appeal with a high standard of reliability. Intelligent Smoke Detector is used with the FW501 Detector Bases. Drift Compensation – Automatic sensitivity adjustment. LEARN MORE FW521 HEAT DETECTOR Intelligent Heat Detector for indoor use with both fixed-temperature alarm and rate-of-rise alarm characteristics Its slim design combines visual appeal with a high standard of reliability. The detector has a Microcontroller Unit (MCU) performing comprehensive self-diagnostic tests, and result analysis. LEARN MORE FW562 ADDRESSABLE DUCT DETECTOR Equipped with a photoelectric smoke detector Indicates the presence of a dangerous amount of combustion product in the ventilation system Compatible with control panels model FW106 and FW106S. Variable size tubes available in 12, 18, 24, 36 and 42 inches. UL/ULC Listed LEARN MORE
- FW752 | Maple Armor
FW752 NON-ADDRESSABLE MANUAL PULL STATION The FW752 and FW752C Non-addressable Manual Stations are UL listed devices according to UL 38 and ULC-S528 for Fire Protective Signaling Systems for indoor use. VIEW DATASHEET NON-ADDRESSABLE MANUAL PULL STATION The FW752 is a normally open initiating device made from durable materials and solid parts for long lasting performance. Capabilities In case of fire, an alarm signal is generated by lifting the cover and pushing the button. A red LED is visible on the station when the fire alarm signal is activated. Compliance UL38/ULC S528 Americans with Disabilities Act The unit adheres to ADA requirements. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 Non-Addressable Manual Pull Station LED Indicator when activated Features a Reset Key Simple Push plate activation Wall Mounting
- 3-FM-5 6V5Ah | Maple Armor
3-FM-5 6V5Ah VIEW DATASHEET MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718