76 items found for ""
- FW6000-B6120 | Maple Armor
FW6000-B6120 VIEW DATASHEET MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718
- 3-FM-12 6V12Ah | Maple Armor
3-FM-12 6V12Ah VIEW DATASHEET MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718
- NOTIFICATION | Maple Armor
DEVICES NOTIFICATION Maple Armor offers a range of fire alarm signaling devices that are easy to install and configure. ABOUT OUR PRODUCTS Maple Armor provides you with nothing but reliable, robust and cost-effective fire alarm devices. All our equipment is UL, ULC, FCC listed as well as FM approved and conform to the highest standards of life safety and property loss prevention. LEARN MORE FW982 MULTI-CANDELA STROBE Multi-candela visual signaling device Light sources generated from white Light Emitting Diodes (LEDs) Five levels of light output are selectable LEARN MORE FW972MN MINI HORN DEVICE WITHOUT BUTTON The horns offer three sound level settings Conventional audible signal appliances that operate on Maple Armor Technologies’ NAC Listed according to UL 464 and ULC-S525 for indoor use LEARN MORE FW972M MINI HORN DEVICE WITH BUTTON The horns offer three sound level settings Conventional audible signal appliances that operate on Maple Armor Technologies’ NAC Listed according to UL 464 and ULC-S525 for indoor use LEARN MORE FW971 FIRE NOTIFICATION HORN Audible Signalization Device Built-in synchronization circuit that can synchronize multiple horns in a complete fire alarm system. Universal pictogram LEARN MORE FW962 MULTI-CANDELA HORN/STROBE Multi-candela visual and/or audible signal appliances Light sources generated from white Light Emitting Diodes (LEDs) Combines both Horn and Strobe features (FW971, FW982) LEARN MORE FW983 ADDRESSABLE STROBE Multi-candela visual signaling device Light sources generated from white Light Emitting Diodes (LEDs) Five levels of light output are selectable LEARN MORE FW973 ADDRESSABLE HORN Audible Signalization Device Built-in synchronization circuit that can synchronize multiple horns in a complete fire alarm system. Universal pictogram LEARN MORE FW963 ADDRESSABLE HORN/STROBE Multi-candela visual and/or audible signal appliances Light sources generated from white Light Emitting Diodes (LEDs) Combines both Horn and Strobe features (FW971, FW982) LEARN MORE
- FW6000-B12180 | Maple Armor
FW6000-B12180 VIEW DATASHEET MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718
- NEW BATTERIES | Maple Armor
NEW BATTERIES Maple Armor offers a great variety of rechargeable batteries for your next fire alarm project application. They come with an 18 month factory warranty. ABOUT OUR PRODUCTS Maple Armor provides you with nothing but reliable, robust and cost-effective fire alarm devices. All our equipment is UL, ULC, FCC listed as well as FM approved and conform to the highest standards of life safety and property loss prevention. LEARN MORE
- FW963 | Maple Armor
FW963 ADDRESSABLE MULTI-CANDELA HORN/STROBE This horn/strobe notification device has the intelligence to report its location (the device address) and status to the FireWatcher series fire alarm control panels. Six levels of light output are selectable. VIEW DATASHEET ADDRESSABLE MULTI-CANDELA HORN/STROBE The FW963AG Horn/Strobe is an addressable multi-candela visual and audible signal appliances with light sources generated from a white LED, listed according to UL 1971, UL 1638, UL 464, ULC-S525 and ULC-S526. Capabilities The temporal tone generated by the horn portion is designed as per ANSI and NFPA72 for standard emergency evacuation signaling requirements. Compliance UL/ULC listed Power Usage The LED light source offers superior performance, including low power consumption and long operating life. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 The strobe appliances produce a flash rate of one flash per second over the Regulated Voltage Range. The appliance has the feature that can synchronize multiple horns and/or strobes in a complete fire alarm system. Wall or Ceiling Mounting
- FW105 | Maple Armor
FW105 ADDRESSABLE FIRE ALARM PANEL The FW105 Addressable Fire Alarm Panel features a compact design wide enough to fit between 16″ studs. It has a 7″ color LCD sequential screen that can display up to 8 active zones simultaneously. VIEW DATASHEET FIRE ALARM PANEL The FW105 features one addressable loop circuit (SLC) with 252 addressable devices/points as well as 6 auxiliary function buttons and 12 LED indicators. FW105 (EXTERIOR) FW105 (INTERIOR) Built-In 30 LED buttons annunciator SD-105 TRIM RING (OPTIONAL) Single flush trim for flush-mount installation Capabilities Network supports up to 32 panels (Class X) or 109 remote annunciators or panels (Class B) Compliance UL/ULC Listed Built-In Annunciator Built-in 30 LED/buttons annunciator MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Datasheet Installation Manual Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 10A power dedicate for signaling circuits Comes with 4 NAC that can be expanded to 8 NAC; 2 Amp per circuit 2 RS232, 1 USB, and 1 RJ45 port on the panel 4 Optional SLC isolator circuits available (Expandable to 8 isolators Class B)
- MA1100 | Maple Armor
MA1100 WEATHERPROOF ANNUNCIATOR ENCLOSURE The weatherproof annunciator enclosure MA1100 is supplied with a heating element used for outdoor applications. VIEW DATASHEET WEATHERPROOF ENCLOSURE The MA1100 surface wall box is designed to be used with the FW123 and FW129 annunciators. The wall box is resistant to temperatures ranging from -40 to 49° C. Capabilities The FW122 LCD annunciator can be used with the enclosure. Up to 109 annunciators can be addressed by the communication circuit. Compliance UL/ULC listed Power Usage It can be used with one 20W (24VAC/VDC) heating option that activates at 1° C and deactivate 17° C. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 Lockable cabinet (Key) Front protective glass Auto-control heating system CSA SPE-1000 Approval CAN/ULC-S527 Approval
- FW131 | Maple Armor
FW131 ADDRESSABLE NAC BOOSTER The new FW131 Booster Power Supply comes in a compact design for faster and easier installation. It has a user friendly interface featuring a LCD screen, 5 function keys and 4 LED indicators! VIEW DATASHEET NAC BOOSTER SUPPLY The FW131 adds 8 Class A or B signaling circuits with a max of 3A per NAC circuit. It features a striking compact design narrow enough to feet in between standard 16″ studs. Capabilities 12A Compact Switching power supply 110 – 120 VAC 60Hz, or 220 – 240 VAC 50Hz Compliance UL/ULC listed Connectivity 2 ways to connect between panels and NAC Boosters – via SLC and Pass Through MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 10A power dedicate to signaling circuits 1A Auxiliary power output 4 form C dry relay contacts
- FW831 | Maple Armor
FW831 RELAY MODULE The FW831 is an addressable relay module that provides two control relay outputs which will be activated simultaneously. The active status of the relay output is indicated by flashing red LED. VIEW DATASHEET FIRE ALARM RELAY MODULE The FW831 is an addressable module and takes one address on the addressable loop (ALU) of the fire alarm control panel. It is a UL listed product according to UL864 and ULC-S527 for Fire Protective Signaling Systems for indoor use. Relays are form-C with all contacts accessible. Capabilities The relay alarm module FW831 provides two control relay outputs which will be activated simultaneously. When the outputs are activated, the device LED will indicate the event condition by fast blinking. Compliance UL864 / ULC S527 Output Configurations It supports both normally closed and normally open output contact configurations. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 The relay model contact Rating: 30VDC 2A, 0.35pf Operating Temperature: 32°F to 120°F (0°C to 49°C) Operating Humidity: 0% to 93% RH Voltage Range: 15 to 28VDC Mounting: FW800 Base
- ALARM PANELS | Maple Armor
ADDRESSABLE FIRE ALARM PANELS Maple Armor supplies you with intelligent and addressable fire alarm control panels that are ideally suited for both new and retrofit commercial, institutional, residential and industrial fire detection and notification applications. ABOUT OUR PRODUCTS Maple Armor provides you with nothing but reliable, robust and cost-effective fire alarm devices. All our equipment is UL, ULC, FCC listed as well as FM approved and conform to the highest standards of life safety and property loss prevention. LEARN MORE FW106S FIRE ALARM CONTROL PANEL Addressable Fire Alarm Control Panel Designed for small and medium scale facilities Suited for both new and retrofit commercial, institutional and industrial fire detection and notification applications. It can support up to 252 Addressable Devices , 2-4 Notification Circuits and 5 Form C Relay Compatible with XNU FW357 Network Card LEARN MORE FW131 ADDRESSABLE NAC BOOSTER 8 Class A or B signaling circuits with a max of 3A per NAC circuit 12A Compact Switching power supply 110 – 120 VAC 60Hz, or 220 – 240 VAC 50Hz 10A power dedicate to signaling circuits 1A Auxiliary power output 4 form C dry relay contacts 3 ways to connect between panels and NAC Boosters – via SLC, via CAN and Pass Through LEARN MORE FW106 FIRE ALARM CONTROL PANEL Addressable Fire Alarm Control Panel Designed for small, medium and large scale facilities Suited for both new and retrofit commercial, institutional and industrial fire detection and notification applications. It can support up to 1008 Addressable Devices , 10 Notification Circuits and 5 Form C Relay Compatible with XNU FW357 Network Card LEARN MORE FW105 ADDRESSABLE FIRE ALARM PANEL Addressable Fire Alarm Control Panel Designed for small and medium scale facilities Built-in 30 LED/buttons annunciator It can support up to 252 Addressable Devices , 4 to 8 Notification Circuits and 5 Form C Relay 6 auxiliary function buttons and 12 LED indicators. LEARN MORE
- FW821 | Maple Armor
FW821 FIRE ALARM I/O MODULE The input-output module FW821 is a UL / ULC listed device according to UL864 and ULC-S527 for fire protection signaling systems for indoor use. VIEW DATASHEET FIRE ALARM I/O MODULE The input line is monitored for open line faults and ground faults, and the contact must thus be wired with an end-of-line resistor. The output line is monitored for open lines, short-circuit faults, ground faults, and external 24VDC power source loss. Capabilities The FW821 input-output module provides one 24VDC output and one feedback input monitor. Compliance UL864 / ULC S527 / FM Listed Addressable The FW821 is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. MORE FEATURES DOCUMENTATION SOFTWARE Datasheet and Installation Manuals Case Studies / Projects Maple Armor Case Studies Customer Support Email: sales@maplearmorgroup.com Phone: +1 (888) 257-7718 Useful to confirm a retroactive action Internal electronic address Compatible with EOLR 10K Ohms (FW421) White surface box available as an option (FW800/801) Status LED indicator