RESOURCES

Device Datasheets

We know how important the bidding process is for any project. These tools will make your bidding process easy and simple.

Control Panels

Firewatcher Modules

Heat/Smoke Detectors

Manual Stations

Notification Devices

Remote Annunciators

FW106

FW106 - Control Panel

FW106 (EN)

FW106W/FW106R/FW106CW/FW106CR

FireWatcher FW106 is an Addressable Fire Alarm Control Panel designed for small to medium-scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. FW106 is a state‐of‐the‐art addressable fire control system that meets the requirements of UL864 10th edition and ULC S527. It supports up to 4 Addressable Signaling Line Circuits of 252 addressable devices / points per loop. It also has a capacity of 2 to 10 Notification Appliance Circuits and 4+1 form C dry relay contacts (4 relays are used for Fire Department connection). The FW106 has a 7’’ LCD with 800 X 480 resolution, 6 auxiliary function keys, and 9 LED indicators making it a highly intuitive fire alarm user interface. It can be connected to 109 remote Panels and Annunciators via an external network to form a fire emergency detection and notification network system.

FW106s

FW121

FW106s-DS-R1.0 (EN)

FW106SW/FW106SR/FW106SCW/FW106SCR

The FW106S is an addressable Fire Alarm Control Panel designed for small scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. A state-of-the-art addressable fire control system that meets the requirements of UL864 10th edition, and ULC S527. It can support 1 addressable loop unit and 252 addressable devices/points, with 2 to 4 Notification Appliance Circuits and 5 form C dry relay contacts.

FW122

FW122

FW122-UM-R1.1 (EN)

FW122W/FW122R/FW122CW/FW122CR

The FW122W, FW122R, FW122CW, FW122CR are Remote LCD Annunciators UL listed according to UL 864 and ULC-S527 for Fire Alarm Systems for indoor use. The FW122W/FW122R/FW122CW/FW122CR have a 7” color LCD display and 800×480 resolutions, 6 auxiliary function keys and 9 LED indicators making it the most intuitive fire-alarm user interface. In total, up to 4 annunciators can be connected to the FW106/FW106C FACP via CAN bus to form a fire emergency detection and notification network system.

FW123

FW123 LCD Remote Annunciator

FW123-DS-R1.0 (EN)

FW123W/FW123R/FW123CW/FW123CR

The Intelligent Remote Compact Annunciator FW123 is designed to be used with the FW106 or the FW106S control panels. The LCD can display 8 simultaneous events. Users can browse more events by pressing the up/down buttons. The FW123 is connected to the FW106/FW106S series panels via the external CAN network and it is powered by an external 24 VDC power source from the panel. Up to109 FW123 remote annunciators can be connected.

FW129

FW129 - LED Remote Annunciator

FW129-DS-R1.0 (EN)

FW129W/FW129R/FW129CW/FW129CR

The FW129 LED Annunciator is used to display zone events from the fire alarm control panel. The FW129 comes with a lockable glass door. A sliding paper strip is used to show zone messages. The FW129 is connected to the control panel via the external network to form an emergency detection and notification network system.

FW201

FW201

FW201-DS-R1.0 (EN)

FW201 AMI
The electronic card FW201 is a subassembly of models FW106 FACP. It integrates two PCBA cards, a 7” LCD module, 11 silicone buttons, and a buzzer. It meets the UL864 10th Edition Listed standard and the ULC-S527 3rd Edition Listed standard.

FW327

FW327

FW327-DS-R1.1 (EN)

FW327 ALU
The module FW327 is a subassembly for the FW106/FW106S FACP (Fire Alarm Control Panel). The ALU supports one addressable loop circuit, which supports up to 252 addressable devices. It can initialize and operate all devices residing on the loop and it communicates all relevant devices and event information, such as alarms and troubles, to the System Central Processing Unit. (CPU). The circuit topology supports Class A or Class B wiring. The address is set by the rotary switch on the board. The valid address range is 1~4. It meets the UL864 10th Edition listed standard and the ULC-S527 3rd Edition listed standard.

FW337

FW337

FW337-DS-R1.1 (EN)

FW337 NOU
The module FW337 is a subassembly for the FW106 FACP (Fire Alarm Control Panel). The NOU supports two independent notification appliance circuits. The circuit topology supports Class A or Class B wiring. The maximum current is 2A per NAC, for a maximum of 4A total per NOU. The address is set by the rotary switch on the board. The valid address range is 1~5. It meets the UL864 10th Edition Listed standard and the ULCS527 3rd Edition Listed standard.

FW347

FW347

FW347-DS-R1.1 (EN)

FW347 ROU
The module FW347 is a subassembly for the FW106 FACP (Fire Alarm Control Panel). The ROU supports five dry contact relays: Alarm Relay, Supervisory Relay, Trouble Relay, Other Signal Relay, and Programmable Relay. The Relay contacts are in the C Form Style. The address is set by the rotary switch on the board. The valid address is 1. It meets the UL864 10th Edition Listed standard and the ULC-S527 3rd Edition Listed standard.

FW357

FW357

FW357-DS-R1.1 (EN)

FW357A XNU
The FW357A is a subassembly of the FW106 series FACP (Fire Alarm Control Panel). It provides two CAN bus terminals to communicate with panels and annunciators in a Network to form a fire emergency detection and notification network system. The address is set by the rotary switch on the front cover. The valid address is 1. It meets the UL864 10th Edition standard and the ULC-S527 3rd Edition standard. FW357A provides both Class X and Class B wiring.

FW391

FW391-PTU

FW391-DS-R1.1 (EN)

FW391 PTU
The power supply FW391 is a subassembly for the FW106 (FACP Fire Alarm Control Panel). It contains an internal transformer that converts 110-120VAC or 220-240VAC input to 24VAC output. It meets the UL86410th Edition Listed standard and the ULC S527 3rdEdition listed standard.

FW397

FW397

FW397-DS-R1.1 (EN)

FW397 PCU
The FW397 power supply and charger is a subassembly for the FW106 FACP (Fire Alarm Control Panel). It provides power supply output to the system (AMI, ALU, NOU, ROU, XNU, Addressable Loop Circuits, Notification Appliance Circuits, Relay output, Network circuits) with regulated 24VDC. The FW397 uses a microprocessor-controlled transfer circuit to switch the power supply for the system to standby batteries when AC power is off or low. It communicates to FW201 AMI to report fault conditions. The address (default is “1”) is set using the rotary switch on the board. It meets the UL864 10th Edition Listed standard and the ULC-S527 3rd Edition Listed standard.

FW412

FW412

FW412-DS-R1.1 (EN)

FW412
The portable programmable device FW412 unit allows the user to read addresses of the existing devices and can program the addresses of new devices.

FW434/435

FW434

FW434-FW435-UM-R1.0 (EN)

FW134R/FW134W/FW135R/FW135W

The FW434 is a module box that allows the installation of multiple Maple Armor modules into one cabinet. FW434 can fit up to 16 modules or 64 mini modules. It integrates an external door, two mounting plates, and a backbox.

The FW435 is a module box that allows the installation of multiple Maple Armor modules into one cabinet. FW435 can fit up to 8 modules or 16 mini modules. It integrates an external door, two mounting plates, and a backbox. 

FW500

FW500

FW500-DS-R1.1 (EN)

FW500
The FW500 Detector Base is designed for use with the FW521 Heat Detector and the FW511 Smoke Detector on FireWatcher Series. Communication takes place over terminal 1 and terminal 2.

FW511

FW511

FW511-DS-R1.1 (EN)

FW511

The FW511 is an intelligent Smoke Detector used with the FW500/FW501 Detector Base, is a UL/ULC listed device according to UL 268 and ULC-S529 for Fire Protective Signaling Systems for indoor use. It features a slim design that combines visual appeal with a high standard of reliability. It responds quickly and dependably to a broad range of fires. The detector has a Microcontroller Unit (MCU), performing comprehensive selfdiagnostic tests and result analysis. The FW511 is intelligent, addressable, and takes one address on the Signaling Line Circuit (SLC) of the fire alarm control panel.

FW521

FW521

FW521-DS-R1.1 (EN)

FW521
The FW521 is an intelligent Heat Detector UL/ULC listed device according to UL 521 and ULC-S530 for Fire Protective Signaling Systems for indoor use with both fixed-temperature alarm and rate-of-rise alarm characters. It features a slim design that combines visual appeal with a high standard of reliability. The detector has a Microcontroller Unit (MCU) performing comprehensive self-diagnostic tests, and result analysis. The FW521 is intelligent, addressable, and takes one address on the signaling Line Circuit (SLC) of the fire alarm control panel.

FW561-RI

FW561-RI

FW561-RI-DS-R1.1 (EN)

FW561-RI
The FW561-RI Remote LED indicator is a component provides visual indication of the device status connected with it. It is compatible with mini-Input Module model FW811M, it shall be located in the same room as FW811M.

FW562

FW562

FW562-UM-R1.0 (EN)

FW562/FW562C

The FW562 is a Photoelectric duct smoke detector designed to provide early detection of smoke and/or the presence of combustion products in ventilation systems. The FW562C detector operates at temperatures from 0ºC to 49ºC (32ºF to 120ºF), can stand relative humidity levels of 0 to 93% and support 300 to 4000 ft/min of air velocity.

FW721

FW106 - Control Panel

FW721-DS-R1.1 (EN)

FW721/FW721C

The FW721 and FW721C Addressable Manual Stations are UL/ULC listed devices according to UL 38 and ULC-S528 for Fire Protective Signalling Systems for indoor use. It is a normally open initiating device made from durable materials and solid parts for long-lasting performance. In case of fire, an alarm signal is generated by lifting the front cover and pushing the plate with the button. A red LED is visible on the station when the fire alarm signal is activated. A reset key (included) with the manual station.

FW722

FW722

FW722-DS-R1.1 (EN)

FW722/FW722C

The FW722 addressable manual station is a UL/ULC listed device according to UL38 and ULC-S528 for Fire Protective Signaling Systems for indoor use. The FW722 is a Manual Station used as part of our Fire Protective Signaling Systems for indoor use. It is a normally open initiating device made from durable materials for long lasting performance.

FW751

FW571

FW751-DS-R1.1 (EN)

FW751/FW751C
The FW751 and FW751C Non-addressable Manual Stations are UL/ULC listed devices according to UL 38 and ULC-S528 for Fire Protective Signaling Systems for indoor use.

FW752

FW752

FW752-DS-R1.1 (EN)

FW752/FW752C

The FW752 and FW752C Non-addressable Manual Stations are UL listed devices according to UL 38 and ULC-S528 for Fire Protective Signaling Systems for indoor use. The FW752 is a normally open initiating device made from durable materials and solid parts for long lasting performance.

FW811

FW811

FW811-DS-R1.0 (EN)

FW811

It is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) of the fire alarm control panel. The input module FW811 monitors a single dry contact and is a UL/ULC listed device according to UL864 and ULCS527 for fire protective signaling systems for indoor use.

FW811M

FW811

FW811M-DS-R1.1 (EN)

FW811M

The Mini input module FW811M monitors a single dry contact and is a UL/ULC listed device according to UL864 and ULC-S527 for fire protective signaling systems for indoor use. It is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel.

FW812

FW812

FW812-DS-R1.1 (EN)

FW812

The FW812 is an intelligent dual input module that supports two Class B input circuits, each of which can monitor a dry contact device. It is an intelligent addressable module and takes two addresses on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel.

FW821

FW821

FW821-DS-R1.0 (EN)

FW821

The FW821 input-output module provides one 24VDC output and one feedback input monitor. The input line is monitored for open line faults and ground faults, and the contact must thus be wired with an end-of-line resistor. The output line is monitored for open lines, short-circuit faults, ground faults, and external 24VDC power source loss. It is a UL/ULC listed device according to UL864 and ULC-S527 for Fire Protective Signalling Systems for indoor use. When the output is activated the device red LED will indicate the event condition by blinking longer. When the feedback is activated the device red LED will indicate the event condition by blinking twice. A return to the normal condition will cause the event to disappear and the device LED indicator will return to blinking every 4 seconds. The FW821 is an intelligent addressable module and takes one address on the Signalling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel.

FW831

FW831

FW831-UM-R1.1 (EN)

FW831

The FW831 relay module provides two control relay outputs which will be activated simultaneously. When the outputs are activated, the device LED will indicate the event condition by red blinking. A return to normal condition will cause the event to disappear and the device LED indicator will return to the red idle condition. The FW831 is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. It is a UL listed product according to UL864 and ULC-S527 for Fire Protective Signaling Systems for indoor use.

FW841

FW831

FW841-DS-R1.0 (EN)

FW841

The FW841 is an intelligent conventional zone module that is intended to interface and monitor 2-wire Class A/B conventional detectors in retrofit or other applications. The initiating zone can support a mix of two-wire conventional automatic detectors as well as normally open dry contact alarm initiating devices such as conventional heat detectors and manual stations.

FW851

FW831

FW851-DS-R1.1 (EN)

FW851

The FW851 isolator module isolates the short point on the signaling line circuit (SLC) or Data Communication Link (DCL). The internal relay will be triggered to disconnect the line power where the short trouble is detected. The device’s yellow LED will indicate the trouble condition by turning steady on. A return to the normal condition will cause the internal relay to switch back to normal position and restore the line power, the device LED indicator will turn off. The FW851 does not occupy an address on the Fire Alarm Control Panel’s SLC/DCL, so no address programming is required. The FW851 is a UL/ULC listed product according to UL864 and ULCS527 for Fire Protective Signaling Systems for indoor use.

FW859

FW831

FW859-DS-R1.1 (EN)

FW859

The module FW859 Supervised In-Suite Isolator Module is designed for installations where disconnection of, or damage to an in-suite audible device will not interfere with the ability of audible devices in other dwelling units, public corridors, or suites to sound on an alarm. The FW859 is designed for residential and hospitality-based applications. The In- Suite Isolator can detect a short circuit condition on a Class A circuit that covers a suite by electrically isolating the wiring.

FW951

FW851

FW951-UM-R1.0 (EN)

FW951

The FW951 Sync Module is a device designed with FW961/FW971/FW981 Horn and/or Strobe with a built-in synchronization circuit to synchronize multiple FW961s in a complete fire alarm system. There are up-to 64 Notification Appliance Circuits (NAC), networked, stand alone or interfacing with the FW951.

FW962/971/982

FW962GR

FW962G-FW971G-FW982G-DS-R1.0 (EN)

FW962 / FW971GR / FW982

The FW962GR/W Horn Strobes and FW982GR/W Strobes are a family of multi-candela visual and audible signal appliances with light sources generated from a white LED, listed according to UL 1971, UL 1638, UL 464, ULC-S525, and ULC-S526 for indoor use. The LED light source offers superior performance, including low power consumption and long operating life. Six levels of light output are selectable.

The FW971GR/W Horns are audible signal appliances listed according to UL 464 and ULC-S525 for indoor use. The temporal tone generated by the horn portion is designed as per ANSI and NFPA72 for standard emergency evacuation signaling requirements. The horn has a feature that can synchronize multiple horns in a complete fire alarm system.

FW963/973/983

FW962GR

FW963G-FW973G-FW983G-DS-R1.0 (EN)

FW963 / FW973 / FW983

The FW963AG Horn/Strobe is an addressable multi-candela visual and audible signal appliances with light sources generated from a white LED, listed according to UL 1971, UL 1638, UL 464, ULC-S525 and ULC-S526.

The FW973AGR/FW973AGW Horns are addressable audible signal appliances listed according to UL 464 and ULC-S525 for indoor use.

The FW983AG Fire Alarm Strobe is part of a family of addressable multi-candela visual and audible signal appliances with light sources generated from a white LED, listed according to UL 1971, UL 1638, UL 464, ULC-S525 and ULC-S526 for indoor use.

FW961/971/981

FW971

FW961-FW971-FW981-UM-R1.0-1 (EN)

FW961 / FW971 / FW981

The FW961/971/981 Horn and/or Strobe is a family of visual and/or audible signal appliances with light sources generated from white Light Emitting Diodes (LEDs) for indoor use. The LED light source offers superior performance, including low power consumption and long operating life.

FW972M

FW972

FW972M-DS-R1.1 (EN)

FW972M

The FW972M Mini Horn is a conventional audible signal appliances that operate on Maple Armor’s NAC, listed according to UL 464 and ULC-S525 for indoor use.  The FW972M is a mini horn, small but powerful! Its low power consumption and the different settings available allow this sound device to fit a wide variety of applications.

FW972M-N

FW972M-N

FW972M-DS-R1.1 (EN)

FW972M-N

The FW972M-N Mini Horn is a conventional audible signal appliances that operate on Maple Armor’s NAC, listed according to UL 464 and ULC-S525 for indoor use.  The FW972M is a mini horn, small but powerful! Its low power consumption and the different settings available allow this sound device to fit a wide variety of applications.

MA1100

MA1100 - Weatherproof Enclosure

MA1100-DS-R1.0 (EN)

MA1100

The weatherproof annunciator enclosure MA1100 is supplied with a heating element used for outdoor applications. The MA1100 surface wall box is designed to be used with the FW123 and FW129 annunciators. The wall box is resistant to temperatures ranging from -40 to 49° C.

10031/32/35

10031-32-35

10031 / 10032/ 10035 (EN)

Steel Battery Unit
  • White power coated steel housing
  • Super bright&Long Lasting LEDs
  • Universal AC input voltage 120V/277V /347V
  • Test switch and AC-ON indicator
  • Universal Mounting: Wall/Ceiling/SideMounting
  • Combo heads adjustable 2 * 2W
  • 120 Mins. battery backup time
  • Suitable for Damp Locations
  • Overcharge and over-discharge protection
  • Operating temperature: 10 ℃ -40 ℃/ 50ºF ~104 ºF
  • Remote heads compatible*
  • Wire connexions provided for remote load (10031)
  • 1 year warranty
  • ULc certified to C22.2-NO141-10

10452

EL Emergency Light

10452 (EN)

Double LED Heads
  • Injection-Molded thermoplastic housing
  • UL 94-5VA flame rating, fire retardant
  • Super bright&Long Lasting LEDs
  • Universal AC input voltage 120-347VAC
  • Test switch and AC-ON indicator
  • 2*1.2W lamps for emergency mode
  • Universal Mounting: Wall/Ceiling Mounting
  • 120 Mins. battery backup time
  • Suitable for Damp Locations
  • Overcharge and over-discharge protection
  • Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
  • 1 year warranty
  • ULc certified to C22.2-NO141-10

10197/10023/24

BES

10024/10023/10197 (EN)

Plastic Running Man
  • Injection-Molded thermoplastic housing
  • UL 94-5VA flame rating, fire retardant
  • Super bright&Long Lasting LEDs
  • Universal AC input voltage 120-347VAC
  • Test switch and AC-ON indicator
  • Universal Mounting: Wall/Ceiling/SideMounting
  • Single or double face with changeable legengds
  • Combo heads adjustable 2 * 1W
  • 120 Mins. battery backup time
  • Suitable for Damp Locations
  • Overcharge and over-discharge protection
  • Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
  • Remote heads compatible(Max 4.8W )*
  • 1 year warranty
  • ULc certified to C22.2-NO141-10

10037

Edge-Lit

10037 (EN)

Edge-lit Running Man
  • Injection-Molded thermoplastic housing
  • UL 94-5VA flame rating, fire retardant
  • Super bright&Long Lasting LEDs
  • Universal AC input voltage 120-347VAC
  • Test switch and AC-ON indicator
  • Universal Mounting: Wall/Ceiling/Side Mounting
  • Single or double face with changeable legengds
  • 3 Hrs. battery backup time
  • Suitable for Damp Locations
  • Overcharge and over-discharge protection
  • Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
  • 1 year warranty
  • ULc certified to C22.2-NO141-10

10351

10351

10351 (EN)

Emergency Exit Sign
  • Injection-Molded thermoplastic housing
  • UL 94 V-0 flame rating, fire retardant
  • Super bright&Long Lasting LEDs
  • Universal AC input voltage 120 / 277VAC
  • Test switch and AC-ON indicator
  • Single / Double face
  • Universal Mounting: Wall/Ceiling / Side Mounting
  • 90 Mins. battery backup time
  • Suitable for Damp Locations
  • Overcharge and over-discharge protection
  • Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
  • 1 year warranty
  • ULc certified to C22.2-NO141-10

10025/26

10025

10025 / 10026 (EN)

Steel Running Man
  • Steel housing
  • Super bright&Long Lasting LEDs
  • Power coated steel frame
  • Universal AC input voltage 120/347VAC
  • Test switch and AC-ON indicator
  • Universal Mounting: Wall/Ceiling/Side Mounting
  • Single or double face with changeable legengds
  • Combo heads adjustable 2 * 0.8W
  • 90 Mins. battery backup time
  • Suitable for Damp Locations
  • Overcharge and over-discharge protection
  • Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
  • 1 year warranty
  • ULc certified to C22.2-NO141-10

10029/195/196

LED Heads

10029 / 10195 / 10196 (EN)

LED Remote Heads
  • Injection-Molded thermoplastic housing
  • Super bright&Long Lasting LEDs
  • UL 94-5VA flame rating, fire retardant
  • Universal DC voltage 3.6-24VDC / 5-24VDC
  • Universal Mounting: Wall/Ceiling Mounting
  • Remote heads adjustable 2W / 4W / 5W
  • Suitable for Dry and Damp Locations
  • Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
  • Insulation:II
  • 1 year warranty
  • Meets requirements of UL924
  • ULc certified to C22.2-NO141-10

10005

ADL

ADL-4-R-W-3CCT-120V (EN)

ADL 4" Slim Panel
  • Aluminum housing with PMMA lampshade
  • Beam Angle 180°
  • Power: 9W
  • IP44
  • Isolated driver steel box with knockouts
  • Switch for selectable color

10316

TUG

TUG-10316 (EN)

T8 Glass Tube
  • Glass tube
  • IP20
  • Humidity: 95%RH
  • Operating temperature 0ºC ~ +45ºC

HBU

HBU

HBU-100-150-200-240W (EN)

UFO High Bay
  • Die cast aluminium heat sink provides
    passive cooling
  • Powder coat paint black
  • Polycarbonate lens standard
  • Stainless steel harware
  • 3ft cabtire 3/18 AWG
  • Standard 120° beam angle, others optional
  • 2 housing size

NWP

NWP

NWP (EN)

Wraparound Light
  • Housing painted white
  • IP rating: IP44
  • Length: 4ft
  • Working temperature 0ºC ~ +40ºC

PLF/PLFH

PLF

PLF/PLFH (EN)

Back-lit Flat Panel Series
  • Extruded aluminium housing
  • Earthquake clip standard
  • IP40, damp location
  • White powder coat paint
  • Flicker free