— RESOURCES
Device Datasheets
We know how important the bidding process is for any project. These tools will make your bidding process easy and simple.
Control Panels
Firewatcher Modules
Heat/Smoke Detectors
Manual Stations
Notification Devices
Remote Annunciators

FW106 (EN)
FW106W/FW106R/FW106CW/FW106CR
FireWatcher FW106 is an Addressable Fire Alarm Control Panel designed for small to medium-scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. FW106 is a state‐of‐the‐art addressable fire control system that meets the requirements of UL864 10th edition and ULC S527. It supports up to 4 Addressable Signaling Line Circuits of 252 addressable devices / points per loop. It also has a capacity of 2 to 10 Notification Appliance Circuits and 4+1 form C dry relay contacts (4 relays are used for Fire Department connection). The FW106 has a 7’’ LCD with 800 X 480 resolution, 6 auxiliary function keys, and 9 LED indicators making it a highly intuitive fire alarm user interface. It can be connected to 109 remote Panels and Annunciators via an external network to form a fire emergency detection and notification network system.
FW106s

FW106s-DS-R1.0 (EN)
FW106SW/FW106SR/FW106SCW/FW106SCR
The FW106S is an addressable Fire Alarm Control Panel designed for small scale facilities. It is ideally suited for both new and retrofit commercial, institutional, and industrial fire detection and notification applications. A state-of-the-art addressable fire control system that meets the requirements of UL864 10th edition, and ULC S527. It can support 1 addressable loop unit and 252 addressable devices/points, with 2 to 4 Notification Appliance Circuits and 5 form C dry relay contacts.

FW122-UM-R1.1 (EN)
FW122W/FW122R/FW122CW/FW122CR
The FW122W, FW122R, FW122CW, FW122CR are Remote LCD Annunciators UL listed according to UL 864 and ULC-S527 for Fire Alarm Systems for indoor use. The FW122W/FW122R/FW122CW/FW122CR have a 7” color LCD display and 800×480 resolutions, 6 auxiliary function keys and 9 LED indicators making it the most intuitive fire-alarm user interface. In total, up to 4 annunciators can be connected to the FW106/FW106C FACP via CAN bus to form a fire emergency detection and notification network system.
FW123

FW123-DS-R1.0 (EN)
FW123W/FW123R/FW123CW/FW123CR
The Intelligent Remote Compact Annunciator FW123 is designed to be used with the FW106 or the FW106S control panels. The LCD can display 8 simultaneous events. Users can browse more events by pressing the up/down buttons. The FW123 is connected to the FW106/FW106S series panels via the external CAN network and it is powered by an external 24 VDC power source from the panel. Up to109 FW123 remote annunciators can be connected.
FW129

FW129-DS-R1.0 (EN)
FW129W/FW129R/FW129CW/FW129CR
The FW129 LED Annunciator is used to display zone events from the fire alarm control panel. The FW129 comes with a lockable glass door. A sliding paper strip is used to show zone messages. The FW129 is connected to the control panel via the external network to form an emergency detection and notification network system.
FW201

FW201-DS-R1.0 (EN)
FW201 AMI
FW327

FW327-DS-R1.1 (EN)
FW327 ALU
FW337

FW337-DS-R1.1 (EN)
FW337 NOU
FW347

FW347-DS-R1.1 (EN)
FW347 ROU
FW357

FW357-DS-R1.1 (EN)
FW357A XNU
FW391

FW391-DS-R1.1 (EN)
FW391 PTU
FW397

FW397-DS-R1.1 (EN)
FW397 PCU
FW412

FW412-DS-R1.1 (EN)
FW412
FW434/435

FW434-FW435-UM-R1.0 (EN)
FW134R/FW134W/FW135R/FW135W
The FW434 is a module box that allows the installation of multiple Maple Armor modules into one cabinet. FW434 can fit up to 16 modules or 64 mini modules. It integrates an external door, two mounting plates, and a backbox.
The FW435 is a module box that allows the installation of multiple Maple Armor modules into one cabinet. FW435 can fit up to 8 modules or 16 mini modules. It integrates an external door, two mounting plates, and a backbox.

FW500-DS-R1.1 (EN)
FW500
FW511

FW511-DS-R1.1 (EN)
FW511
The FW511 is an intelligent Smoke Detector used with the FW500/FW501 Detector Base, is a UL/ULC listed device according to UL 268 and ULC-S529 for Fire Protective Signaling Systems for indoor use. It features a slim design that combines visual appeal with a high standard of reliability. It responds quickly and dependably to a broad range of fires. The detector has a Microcontroller Unit (MCU), performing comprehensive selfdiagnostic tests and result analysis. The FW511 is intelligent, addressable, and takes one address on the Signaling Line Circuit (SLC) of the fire alarm control panel.
FW521

FW521-DS-R1.1 (EN)
FW521
FW561-RI

FW561-RI-DS-R1.1 (EN)
FW561-RI
FW562

FW562-UM-R1.0 (EN)
FW562/FW562C
The FW562 is a Photoelectric duct smoke detector designed to provide early detection of smoke and/or the presence of combustion products in ventilation systems. The FW562C detector operates at temperatures from 0ºC to 49ºC (32ºF to 120ºF), can stand relative humidity levels of 0 to 93% and support 300 to 4000 ft/min of air velocity.

FW721-DS-R1.1 (EN)
FW721/FW721C
The FW721 and FW721C Addressable Manual Stations are UL/ULC listed devices according to UL 38 and ULC-S528 for Fire Protective Signalling Systems for indoor use. It is a normally open initiating device made from durable materials and solid parts for long-lasting performance. In case of fire, an alarm signal is generated by lifting the front cover and pushing the plate with the button. A red LED is visible on the station when the fire alarm signal is activated. A reset key (included) with the manual station.
FW722

FW722-DS-R1.1 (EN)
FW722/FW722C
The FW722 addressable manual station is a UL/ULC listed device according to UL38 and ULC-S528 for Fire Protective Signaling Systems for indoor use. The FW722 is a Manual Station used as part of our Fire Protective Signaling Systems for indoor use. It is a normally open initiating device made from durable materials for long lasting performance.
FW751

FW751-DS-R1.1 (EN)
FW751/FW751C
FW752

FW752-DS-R1.1 (EN)
FW752/FW752C
The FW752 and FW752C Non-addressable Manual Stations are UL listed devices according to UL 38 and ULC-S528 for Fire Protective Signaling Systems for indoor use. The FW752 is a normally open initiating device made from durable materials and solid parts for long lasting performance.

FW811-DS-R1.0 (EN)
FW811
It is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) of the fire alarm control panel. The input module FW811 monitors a single dry contact and is a UL/ULC listed device according to UL864 and ULCS527 for fire protective signaling systems for indoor use.
FW811M

FW811M-DS-R1.1 (EN)
FW811M
The Mini input module FW811M monitors a single dry contact and is a UL/ULC listed device according to UL864 and ULC-S527 for fire protective signaling systems for indoor use. It is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel.
FW812

FW812-DS-R1.1 (EN)
FW812
The FW812 is an intelligent dual input module that supports two Class B input circuits, each of which can monitor a dry contact device. It is an intelligent addressable module and takes two addresses on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel.
FW821

FW821-DS-R1.0 (EN)
FW821
The FW821 input-output module provides one 24VDC output and one feedback input monitor. The input line is monitored for open line faults and ground faults, and the contact must thus be wired with an end-of-line resistor. The output line is monitored for open lines, short-circuit faults, ground faults, and external 24VDC power source loss. It is a UL/ULC listed device according to UL864 and ULC-S527 for Fire Protective Signalling Systems for indoor use. When the output is activated the device red LED will indicate the event condition by blinking longer. When the feedback is activated the device red LED will indicate the event condition by blinking twice. A return to the normal condition will cause the event to disappear and the device LED indicator will return to blinking every 4 seconds. The FW821 is an intelligent addressable module and takes one address on the Signalling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel.
FW831

FW831-UM-R1.1 (EN)
FW831
The FW831 relay module provides two control relay outputs which will be activated simultaneously. When the outputs are activated, the device LED will indicate the event condition by red blinking. A return to normal condition will cause the event to disappear and the device LED indicator will return to the red idle condition. The FW831 is an intelligent addressable module and takes one address on the Signaling Line Circuit (SLC) or Data Communication Link (DCL) of the fire alarm control panel. It is a UL listed product according to UL864 and ULC-S527 for Fire Protective Signaling Systems for indoor use.
FW841

FW841-DS-R1.0 (EN)
FW841
The FW841 is an intelligent conventional zone module that is intended to interface and monitor 2-wire Class A/B conventional detectors in retrofit or other applications. The initiating zone can support a mix of two-wire conventional automatic detectors as well as normally open dry contact alarm initiating devices such as conventional heat detectors and manual stations.
FW851

FW851-DS-R1.1 (EN)
FW851
The FW851 isolator module isolates the short point on the signaling line circuit (SLC) or Data Communication Link (DCL). The internal relay will be triggered to disconnect the line power where the short trouble is detected. The device’s yellow LED will indicate the trouble condition by turning steady on. A return to the normal condition will cause the internal relay to switch back to normal position and restore the line power, the device LED indicator will turn off. The FW851 does not occupy an address on the Fire Alarm Control Panel’s SLC/DCL, so no address programming is required. The FW851 is a UL/ULC listed product according to UL864 and ULCS527 for Fire Protective Signaling Systems for indoor use.
FW859

FW859-DS-R1.1 (EN)
FW859
The module FW859 Supervised In-Suite Isolator Module is designed for installations where disconnection of, or damage to an in-suite audible device will not interfere with the ability of audible devices in other dwelling units, public corridors, or suites to sound on an alarm. The FW859 is designed for residential and hospitality-based applications. The In- Suite Isolator can detect a short circuit condition on a Class A circuit that covers a suite by electrically isolating the wiring.
FW951

FW951-UM-R1.0 (EN)
FW951
The FW951 Sync Module is a device designed with FW961/FW971/FW981 Horn and/or Strobe with a built-in synchronization circuit to synchronize multiple FW961s in a complete fire alarm system. There are up-to 64 Notification Appliance Circuits (NAC), networked, stand alone or interfacing with the FW951.

FW962G-FW971G-FW982G-DS-R1.0 (EN)
FW962 / FW971GR / FW982
The FW962GR/W Horn Strobes and FW982GR/W Strobes are a family of multi-candela visual and audible signal appliances with light sources generated from a white LED, listed according to UL 1971, UL 1638, UL 464, ULC-S525, and ULC-S526 for indoor use. The LED light source offers superior performance, including low power consumption and long operating life. Six levels of light output are selectable.
The FW971GR/W Horns are audible signal appliances listed according to UL 464 and ULC-S525 for indoor use. The temporal tone generated by the horn portion is designed as per ANSI and NFPA72 for standard emergency evacuation signaling requirements. The horn has a feature that can synchronize multiple horns in a complete fire alarm system.
FW963/973/983

FW963G-FW973G-FW983G-DS-R1.0 (EN)
FW963 / FW973 / FW983
The FW963AG Horn/Strobe is an addressable multi-candela visual and audible signal appliances with light sources generated from a white LED, listed according to UL 1971, UL 1638, UL 464, ULC-S525 and ULC-S526.
The FW973AGR/FW973AGW Horns are addressable audible signal appliances listed according to UL 464 and ULC-S525 for indoor use.
The FW983AG Fire Alarm Strobe is part of a family of addressable multi-candela visual and audible signal appliances with light sources generated from a white LED, listed according to UL 1971, UL 1638, UL 464, ULC-S525 and ULC-S526 for indoor use.
FW961/971/981

FW961-FW971-FW981-UM-R1.0-1 (EN)
FW961 / FW971 / FW981
The FW961/971/981 Horn and/or Strobe is a family of visual and/or audible signal appliances with light sources generated from white Light Emitting Diodes (LEDs) for indoor use. The LED light source offers superior performance, including low power consumption and long operating life.
FW972M

FW972M-DS-R1.1 (EN)
FW972M
The FW972M Mini Horn is a conventional audible signal appliances that operate on Maple Armor’s NAC, listed according to UL 464 and ULC-S525 for indoor use. The FW972M is a mini horn, small but powerful! Its low power consumption and the different settings available allow this sound device to fit a wide variety of applications.
FW972M-N

FW972M-DS-R1.1 (EN)
FW972M-N
The FW972M-N Mini Horn is a conventional audible signal appliances that operate on Maple Armor’s NAC, listed according to UL 464 and ULC-S525 for indoor use. The FW972M is a mini horn, small but powerful! Its low power consumption and the different settings available allow this sound device to fit a wide variety of applications.
MA1100

MA1100-DS-R1.0 (EN)
MA1100
The weatherproof annunciator enclosure MA1100 is supplied with a heating element used for outdoor applications. The MA1100 surface wall box is designed to be used with the FW123 and FW129 annunciators. The wall box is resistant to temperatures ranging from -40 to 49° C.
10031/32/35

10031 / 10032/ 10035 (EN)
Steel Battery Unit
- White power coated steel housing
- Super bright&Long Lasting LEDs
- Universal AC input voltage 120V/277V /347V
- Test switch and AC-ON indicator
- Universal Mounting: Wall/Ceiling/SideMounting
- Combo heads adjustable 2 * 2W
- 120 Mins. battery backup time
- Suitable for Damp Locations
- Overcharge and over-discharge protection
- Operating temperature: 10 ℃ -40 ℃/ 50ºF ~104 ºF
- Remote heads compatible*
- Wire connexions provided for remote load (10031)
- 1 year warranty
- ULc certified to C22.2-NO141-10
10452

10452 (EN)
Double LED Heads
- Injection-Molded thermoplastic housing
- UL 94-5VA flame rating, fire retardant
- Super bright&Long Lasting LEDs
- Universal AC input voltage 120-347VAC
- Test switch and AC-ON indicator
- 2*1.2W lamps for emergency mode
- Universal Mounting: Wall/Ceiling Mounting
- 120 Mins. battery backup time
- Suitable for Damp Locations
- Overcharge and over-discharge protection
- Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
- 1 year warranty
- ULc certified to C22.2-NO141-10
10197/10023/24

10024/10023/10197 (EN)
Plastic Running Man
- Injection-Molded thermoplastic housing
- UL 94-5VA flame rating, fire retardant
- Super bright&Long Lasting LEDs
- Universal AC input voltage 120-347VAC
- Test switch and AC-ON indicator
- Universal Mounting: Wall/Ceiling/SideMounting
- Single or double face with changeable legengds
- Combo heads adjustable 2 * 1W
- 120 Mins. battery backup time
- Suitable for Damp Locations
- Overcharge and over-discharge protection
- Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
- Remote heads compatible(Max 4.8W )*
- 1 year warranty
- ULc certified to C22.2-NO141-10
10037

10037 (EN)
Edge-lit Running Man
- Injection-Molded thermoplastic housing
- UL 94-5VA flame rating, fire retardant
- Super bright&Long Lasting LEDs
- Universal AC input voltage 120-347VAC
- Test switch and AC-ON indicator
- Universal Mounting: Wall/Ceiling/Side Mounting
- Single or double face with changeable legengds
- 3 Hrs. battery backup time
- Suitable for Damp Locations
- Overcharge and over-discharge protection
- Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
- 1 year warranty
- ULc certified to C22.2-NO141-10
10351

10351 (EN)
Emergency Exit Sign
- Injection-Molded thermoplastic housing
- UL 94 V-0 flame rating, fire retardant
- Super bright&Long Lasting LEDs
- Universal AC input voltage 120 / 277VAC
- Test switch and AC-ON indicator
- Single / Double face
- Universal Mounting: Wall/Ceiling / Side Mounting
- 90 Mins. battery backup time
- Suitable for Damp Locations
- Overcharge and over-discharge protection
- Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
- 1 year warranty
- ULc certified to C22.2-NO141-10
10025/26

10025 / 10026 (EN)
Steel Running Man
- Steel housing
- Super bright&Long Lasting LEDs
- Power coated steel frame
- Universal AC input voltage 120/347VAC
- Test switch and AC-ON indicator
- Universal Mounting: Wall/Ceiling/Side Mounting
- Single or double face with changeable legengds
- Combo heads adjustable 2 * 0.8W
- 90 Mins. battery backup time
- Suitable for Damp Locations
- Overcharge and over-discharge protection
- Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
- 1 year warranty
- ULc certified to C22.2-NO141-10
10029/195/196

10029 / 10195 / 10196 (EN)
LED Remote Heads
- Injection-Molded thermoplastic housing
- Super bright&Long Lasting LEDs
- UL 94-5VA flame rating, fire retardant
- Universal DC voltage 3.6-24VDC / 5-24VDC
- Universal Mounting: Wall/Ceiling Mounting
- Remote heads adjustable 2W / 4W / 5W
- Suitable for Dry and Damp Locations
- Operating temperature: 0 ℃ -40 ℃/ 32 ºF ~104 ºF
- Insulation:II
- 1 year warranty
- Meets requirements of UL924
- ULc certified to C22.2-NO141-10
10005

ADL-4-R-W-3CCT-120V (EN)
ADL 4" Slim Panel
- Aluminum housing with PMMA lampshade
- Beam Angle 180°
- Power: 9W
- IP44
- Isolated driver steel box with knockouts
- Switch for selectable color
10316

TUG-10316 (EN)
T8 Glass Tube
- Glass tube
- IP20
- Humidity: 95%RH
- Operating temperature 0ºC ~ +45ºC
HBU

HBU-100-150-200-240W (EN)
UFO High Bay
- Die cast aluminium heat sink provides
passive cooling - Powder coat paint black
- Polycarbonate lens standard
- Stainless steel harware
- 3ft cabtire 3/18 AWG
- Standard 120° beam angle, others optional
- 2 housing size
NWP

NWP (EN)
Wraparound Light
- Housing painted white
- IP rating: IP44
- Length: 4ft
- Working temperature 0ºC ~ +40ºC
PLF/PLFH

PLF/PLFH (EN)
Back-lit Flat Panel Series
- Extruded aluminium housing
- Earthquake clip standard
- IP40, damp location
- White powder coat paint
- Flicker free